Hygienic air treatment: protect your product without paying double for your air

Protect your product without inflating your energy bill.

Angle noire

Reduce airborne contamination without sending your energy bill through the roof

In an agri-food plant, air contacts the product more often than any surface. It enters through dock doors, circulates between raw and cooked areas, condenses on cold ceilings, and drips back down.

We design, install, and maintain hygienic air treatment systems that curb this airborne contamination, and we back the resulting energy consumption with a written guarantee.

Hygienic air treatment, sanitary air conditioning, ultra-hygienic air: what does it all mean?

All three terms refer to the same principle: a system that controls air quality wherever the product is exposed, rather than merely heating, cooling, and circulating air. Four parameters are managed together.

  • Filtration, which sets the particulate and microbiological load of the supply air.
  • Differential pressure between zones, which determines which way air flows whenever a door opens.
  • Airflow direction and velocity, which dictate whether air travels from clean to soiled zones or the reverse.
  • Humidity and temperature, which govern condensation, microbial growth, and, in aging and curing processes, product yield itself.

A standard industrial ventilation system manages only the last two. A hygienic system controls all four, and documents them.

Hygienic air treatment essentials

Reducing airborne contamination: measure before you buy

The first thing we do upon entering a plant is measure differential pressures across zones, door by door. Quite often, an area intended to be under positive pressure is actually under negative pressure because an exhaust hood added three years earlier extracts more air than the air treatment unit supplies. The hygiene plan looks flawless on paper, but the air behaves in the exact opposite way.

Next come actual airflow rates at the diffusers, air changes per hour, surface temperatures of ceilings and ducts, and condensation points. This data-driven diagnosis governs everything else. In many cases, it points to system rebalancing and filter replacement rather than installing a brand-new unit.

When equipment does need replacement, we install ModulAir air treatment units with Climinox casings, engineered for washdown and lasting airtightness. Washable textile ducts distribute air evenly without condensation points. System monitoring is handled by MyPortal3E, which logs setpoints and spots discrepancies before production teams notice them.

Safe Food for Canadians Regulations: what your preventive control plan must demonstrate

The Safe Food for Canadians Regulations (SOR/2018-108) require operators to develop, document, and implement a preventive control plan, and to verify that control measures are effective (1).

The Canadian Food Inspection Agency states that sources and areas of condensation must be addressed in hazard analyses, and that improving airflow and ventilation qualifies as an acceptable control measure (2).

Put simply, an inspector does not ask what unit you purchased. They ask how you prove it delivers the required performance. Our pressure logs, airflow maps, and MyPortal3E historical data feed directly into your preventive control plan compliance file. In meat and cured-meat plants, our airflow audits bring installations up to Canadian standards and uncover up to 45% in energy savings on the same project (4).

Hygiene and energy efficiency: calculated trade-offs,not guesswork

Ramping up the air change rate is the knee-jerk reaction to hygiene challenges. It is also the most expensive: every cubic metre of outdoor air must be heated in January and dehumidified in July. A plant that jumps from 8 to 14 air changes per hour (ACH) adds 75% to the outdoor-air portion of its thermal bill, without ever proving it reduced contamination.

The cost-effective route starts with airflow direction and pressure cascades. Redirecting air rather than supplying more of it solves a significant portion of issues. Heat recovery on exhaust air, glycol run-around coils or thermal wheels, and filtered recirculation (where zone requirements allow) follow only after.

Heat recovery and the thermal envelope are also eligible categories for the 10% or 15% multi-measure bonus under Hydro-Québec’s Efficient Solutions Program since March 31, 2026 (3).

When we commit to results, we put them in writing. The written performance guarantee from Soteck Clauger is a contractual commitment on energy outcomes, subject to defined conditions. That is what sets an equipment vendor apart from a true performance partner.

Cleanroom, clean zone, controlled-environment zone: where do you draw the line?

Many food processing plants refer to a cleanroom when describing a clean, controlled-environment zone. The distinction matters, as it can multiply the cost per square metre.

A controlled-environment zone maintains specific temperature, humidity, and positive pressure setpoints, paired with risk-appropriate filtration. This is what aging, fresh-product packaging, curing, and most cutting rooms require. A cleanroom in the normative sense also holds a verified ISO cleanliness class, with design, installation, and performance qualification (DQ, IQ, PQ). That level of control is reserved for pharmaceuticals, microelectronics, and certain sensitive food processes.

We design and install the former. For certified cleanrooms, the Clauger Group delivers its specialized cleanroom expertise through its subsidiary, Valtria. In both cases, humidity control remains the most demanding parameter to maintain, and it is the first area we address.

What Québec plants gain

A Québec manufacturer was unknowingly losing $400,000 per year until an airflow management audit brought the figures to light (5). The issue was not equipment failure. The system was running as originally specified, but not as the plant actually needed. The Flash Audit takes just one day, involves zero commitment, and routinely reveals 15% to 25% in annual energy bill savings. It is eligible for incentives across several provinces (4).

Request your Flash Audit

Whywork with us

Soteck Clauger was founded in Victoriaville in 1993, where its head office remains today. The team now counts over 125 specialists across Victoriaville, Montréal, and Trois-Rivières: engineers, refrigeration mechanics, pipefitters, ventilation technicians, and electricians who spend their weeks inside agri-food and manufacturing plants across Eastern Canada. Since 2019, the company has been part of the French Clauger Group, providing direct access to stainless-steel units from Climinox and Valtria’s cleanroom engineering. Soteck Clauger is also the exclusive Canadian distributor of Sodistra polyester air treatment units, including Saniclim® and Basiclim®, designed for wet areas and corrosive environments.

Inside a plant, air hygiene, refrigeration, and energy costs are inextricably linked. Waste heat rejected by your NH₃ or CO₂ refrigeration system can preheat the outdoor air your clean zones require all winter. That only works if the same team looks after both systems. With us, the engineers who measure your pressures design the solution, and the technicians who commission the equipment return to maintain it. You deal with a single point of contact, from baseline field diagnostics to long-term maintenance agreements.

Our commitments are backed by numbers. If an area drifts outside its setpoints, a technician arrives on site within four hours, 24/7. Target energy reductions are backed by a conditional written performance guarantee. As a qualified energy services company (ESCO) and SOFIAC partner, Soteck Clauger can carry a project that is fully financed and repaid from measured savings, without touching the plant’s capital.

FAQ:your questionsabout hygienic air in your plant

These six questions come up in virtually every plant we visit, from cutting rooms to aging rooms. Here are concise answers designed to resolve investment committee discussions and support your preventive control files.

It is a system that comprehensively manages four variables where food products are exposed: supply air filtration, differential pressure across zones, airflow direction and velocity, and combined temperature and humidity. Conventional industrial ventilation handles only the latter two.

In practical terms, filtration is selected according to the ISO 16890 classification, frequently ePM1 for supply air in critical zones. The pressure cascade is calibrated with differentials of a few pascals between adjacent rooms, generally 5 to 15 Pa. Humidity is controlled relative to cold surface dew points rather than just an ambient relative humidity setpoint. Every metric is tracked, recorded, and verified to ensure full audit readiness.

By prioritizing airflow direction and pressure cascades over higher air change rates. Redirecting air is far more cost-effective than supplying greater volumes, since each cubic metre of outdoor air requires heating in the winter and dehumidification in the summer.

To put it into perspective, heating 1,000 m³/h of outdoor air from −20°C to 20°C requires 13 to 15 kW of continuous power. In the field, we first measure door-to-door pressures using micromanometers, map flow patterns with smoke testing, and then balance supply air and exhaust air flows. An exhaust hood added after commissioning is often enough to reverse an entire pressure cascade. Heat recovery on exhaust air is then applied to whatever outdoor air volume cannot be avoided.

The Safe Food for Canadians Regulations (SOR/2018-108) require operators to document a preventive control plan and verify the efficacy of their control measures (1). The CFIA requires condensation sources to be included in hazard analyses and recognizes airflow and ventilation upgrades as acceptable control measures (2).

For air systems, compliance evidence relies on dated records: cross-zone pressure mappings, airflow measurements at diffusers, filter pressure drop monitoring and replacement schedules, surface temperatures at known condensation points, and logged control setpoints. These records satisfy both the monitoring and verification mandates of the plan. Inspectors look for documented anomalies that were caught and resolved, not an equipment list.

A controlled-environment zone maintains specific temperature, humidity, and positive pressure setpoints with risk-appropriate filtration. A cleanroom additionally maintains a verified ISO cleanliness class, supported by design, installation, and performance qualification protocols.

The ISO 14644-1 standard classifies airborne particulate cleanliness by concentration per cubic metre. An ISO 8 cleanroom allows up to 3,520,000 particles of 0.5 µm or larger per cubic metre; ISO 7 allows ten times fewer, and ISO 5 allows a thousand times fewer (6). Meeting these classifications demands very high-efficiency terminal filters, high airflow rates, and periodic certification testing. The cost per square metre is substantially higher, and standard cutting, aging, and packaging rooms rarely require it.

Rarely as a first measure. Increasing ventilation from 8 to 14 air changes per hour (ACH) increases the outdoor air portion of your heating bill by 75% without demonstrating any reduction in contamination. Pressure and airflow diagnostics will pinpoint whether the root issue is volumetric flow or directional control.

The calculation is straightforward: air changes per hour equal total flow rate divided by room volume. In a 1,000 m³ space, increasing from 8 to 14 ACH adds 6,000 m³/h of air to treat. Fan power requirements scale approximately with the cube of the flow rate: on a given installation, a 75% increase in airflow demands roughly five times more electrical power. Increasing airflow achieves nothing if air flows in the wrong direction.

The Soteck Clauger Flash Audit takes one day and requires no commitment. It quantifies losses, prospective savings, and available incentives, and qualifies for incentives in several provinces. It typically identifies 15% to 25% in annual savings (4).

The day is spent on site: diagnosing installations and equipment, identifying waste and excess energy consumption, and delivering tailored recommendations for your sector. You receive a quantified action plan, preliminary budgeting, and an estimated return on investment (ROI), averaging two to three years on recommended measures. Government incentives can cover up to 50% of eligible costs depending on the program (4). When diagnostics reveal flow imbalances, an airflow management audit provides deeper engineering analysis.

Content verified by our expert:
Picture of pierre-andré poirier guay

Pierre-André Poirier Guay

Director, Engineering & Innovation

View his full profile

Pierre-André Poirier Guay, Eng., Director of Engineering and Innovation at Soteck Clauger since 2006. With an entrepreneurial background in plumbing in Centre-du-Québec, he brings over 20 years of experience in building systems and industrial processes. He guides technical strategy, aligning high performance and energy efficiency with practical field realities.

Page written on October 8, 2026, using regulatory data and funding program criteria verified as of that date.

To contact Pierre-André

Conclusion and sources

In an agri-food plant, hygienic air treatment is not an optional comfort feature tacked onto industrial ventilation. It is the core system controlling what the air deposits onto food products across cutting rooms, packaging lines, aging rooms, and cleanrooms alike. Four parameters are actively balanced: supply air filtration, positive pressure cascades between clean and soiled zones, airflow direction and velocity, and the temperature-humidity relationship governing condensation.

Controlling airborne contamination in food processing plants requires documented proof as much as proper hardware. The Safe Food for Canadians Regulations require a documented preventive control plan and objective proof that control measures perform as intended.

A dated pressure mapping report, diffuser airflow measurements, and accessible setpoint logs carry far more weight during an inspection than an equipment invoice.

That leaves the balance between hygiene and energy efficiency, which must be engineered rather than estimated. Increasing air change rates is the default reflex, but also the most expensive, as outdoor air must be heated in January and dehumidified in July. Redirecting air is far more cost-effective than supplying more volume.

Our Flash Audit measures both dynamics in a single day and pinpoints the heat recovery potential unlocked by corrective action.

  1. Government of Canada, Safe Food for Canadians Regulations, SOR/2018-108, preventive control plan requirements. View regulation
  2. Canadian Food Inspection Agency, Recommended preventive controls, Condensation, page accessed on October 8, 2026. View page
  3. Hydro-Québec, Efficient Solutions and LogisVert Efficient Homes Programs: program changes and version 6.0 of the OSE tool, multi-measure bonus, notice dated March 31, 2026. View page
  4. Soteck Clauger, Flash Energy Audit, verified field results in meat and cured products and average annual savings. View page
  5. Soteck Clauger, We were losing $400,000 a year without realizing it, airflow management audit, 2025. Read article
  6. International Organization for Standardization, ISO 14644-1:2015, Cleanrooms and associated controlled environments, Part 1: Classification of air cleanliness by particle concentration, 2nd edition, reaffirmed in 2021. View standard